WebWayWorld Logo 2018

 

Remote Manager - NETWORX & HILLS Reliance

Interface to DL900 WIN: This UDL uses virtual serial ports as the communication interface to the RM. Once you have created two serial ports virtually linked, the UDL must be configured to open one port and an RM session configured to open the other port for communications to be successful. The connection is handled by using the site ID/Account as the phone number to dial.

 

Create an RM DL900 WIN UDL session:

1)Click on the [Sessions] menu item and select the [New] menu item. RM will display a new [Session Configuration] page.



2) Give the new session a name by entering a name in the [Session Name] edit box.

3) Then click on the [Session Type] drop down list box and select DL900 from the list.

4) Click on the [SSH Server 1 IP] edit box and enter the IP address of PC that is running the SSH Server and WebWayOne’s MCT application.

 

5) Click on the [Save] button. Click on the [Modify] button and the [Edit properties] button. The following form will be displayed.



You may need to change the COM port to one of the virtual serial ports you created and selected for the RM to listen on. COM10 is the default port for all sessions using the serial interfaces.

Note: You can use the same virtual serial ports for all your different UDL connections, but if you wish to use more than one UDL at the same time, you must different COM ports for each session.



6) Click on the [Accept] button.

 

DL900 WIN set up for NETWORX and HILLS Reliance

Notes:

 Using com0com for DL900 WIN requires a different configuration for communications to Remote Manager to work. Follow normal process of installing com0com and creating com pairs.

 A standard modem driver needs to be created and linked to the virtual port opposite to Remote Managers port. This modem driver is what you get DL900 WIN to select to communicate with Remote Manager.

 

How to create and install a standard modem driver in Windows7:

Go to Start->Control Panel->Phone and Modem. Select [Modems] tab.



Press the [Add...] button



Tick the [Don't detect my modem] tick box and press the [Next] button.



Select the 'Standard 56000 bps Modem' from the [Models] list and press the [Next] button.



Select the com0com virtual port and press the [Next] and [Finish] button.



Using DL900WIN

1) Run up the UDL program and login.

Default Operator: caddx

Default Password: 1234

Note: Seems you have to enter the above username and password twice!!!

2) Select menu item [Program][Setup][Modem setup].



3) In [Connect using...] select the modem driver you created earlier.

4) In [Initialization string description] choose [48) Hayes Accura 288] by using scroll bar.

5) Save changes.

6) Either open an existing customer or create a new one.



7) Fill in appropriate details such as the correct [Panel].

8) Make sure the [Panel phone] field is set to the SPT account\site number.

9) Save changes.

10) To connect to the desired panel, select menu item [Download][Connect][Connect using modem].

Support

Knowledge Base

Panel Guides

Downloads

FAQs