• A Guardall external dialler module is required on: PX500, PX250HS, QX18, QX34, PX18, PX34, PX80
  • Serial Connectivity is also available for connectivity please refers to the modem capture Guardall Guide for Instructions.
  • A Guardall GSR Dongle code is required for any Guardall installation,(this can be a dummy number if a dongle is not available)
  • WebWayOne Guide - 

    Guardall - Modem Capture Guide Guardall - Modem Capture Guide (515 KB)

  • Click here for Remote Manager and Upload / Download settings 
  • Modem Capture Connection
Connect the A and B ‘PSTN’ terminals and ground on the WebWay to the A and B telephone connections on the Guardall alarm panel.


 Guardall Connection WebWay Modem Capture

Panel Programming

Menu 11 Menu 12 – GSR 1 Menu 13
1.     Select menu 11 - telephone number 1 1.     Enter S/N <______> * 1.     Select the SM (Chosen in Menu 11)
2.     Select Tel Number <1> 2.     Enter GSR ID <______> ** 2.     Set chosen SM to type  <serial>
3.     Enter Tel Number <01234 567890>   3.     Select Enable <Auto>   3.     Set SM Baud rate to <9600>
4.     Select Format <SIA> 4.     Enter IP Address <0> 4.     Ensure all other SMs and Dialers have the type disabled
5.     Select Module <Int Dir>  or <Ext. Dlr> 5.     Select CallBack <Off> 5.     The module required is either Internal or external dialler  the type must be PSTN or PSTN&GSM
6.     Select Auto Test <Off> 6.     Select Reset <On> 6.     If the type is PSTN&GSM, there will be ROUTE menus to set
7.     Select Attempt <0> 7.     Select Unset <On> 7.     The first ROUTE menu must be set to PSTN and all others disabled
8.     Select Backup <0> 8.     Select Code <On>
9.    Select Alarm <On> 9.     Select Clock <On> Menu 20
9.     Select Set/Unset <On> 10.   Select Bypass <On> 1.     Select Area ID
10.   Select Bypass <On> 11.    Select Soak <On> 2.     Enter <0>
11.   Select Trouble <On> 12.   Select Log <On> 3.     Select system <_____>***
12.   Select Log On <On> 13.   Select Config RD <On> 4.     Enter <1>
13.   Select Eng On <On> 14.   Select Config WR <On> 5.     Select Area <_____>***
14.   Select Reset <On> 15.   Select PINs RW <Off> 6.     Press X button four times
15.   Select Restore <On> 16.   Select A. Log Upload <0> 7.     Select 05 to log out
16.   Press X button twice 17.   Select Exit Time <1>
18.   Select KP Message <On> * Program the site/Chip ID here. If this configuration option is not found in menu 12, then please check menu 4.
19.   Select Virtual KP <On>  **GSR Dongle serial number, this number must match in the WebWay SPT. 
20.   Select Poll time <0> *** Enter the Site/ Chip ID here.
21.   Select X button once

Important: Please note which Serial module you have connected to (if there are multiple) in order to make sure the panel programming matches. 

IMPORTANT - GSR Dongle Code

For remote management of the panel the WebWay SPT and the Guardall panel must be programmed with same dongle number as used with the GSR panel software.
If remote management is not in use the WebWay and Guardall panel still require a GSR code to send SIA alarms. This can be a generic number, e.g.; 12345.
The Webway and Guardall cannot communicate if this number does not match. The dongle number can be entered manually via menu G in the WebWay SPT same manner as for “Auto Take-On” which uses menu D. 
For site roll outs we can pre populate the WebWay SPT with the GSR code. For more information on this, or and queries on the GSR code please contact support on, 01635 231514 or support@webwayone.co.uk.