Serial Connectivity for Scantronic 9X5X

The following panels have been integrated to the WebWay signalling solution Scantronic 9X5X

Requirements

WebWay Modem Capture Module (22- 5059) required for communications
Cooper Security software for secure remote management



WebWayOne Guide -  

Scantronic 9X5X WebWay Guide Scantronic 9X5X WebWay Guide (357 KB)


Modem Capture Connection

Connect the WebWay modem capture module A and B to the Scantronic 9X5X A and B PSTN cable connectors. Connect the WebWay PWR + and - to the GND and +12V terminals on the Scantronic Panel


WebWay SPT MCM Connection

Panel Programming

1. [Installer Mode] will be displayed
2. Input 101, press <Enter>
3. [101:Comms] will be displayed, press 1 (Single) &  <Enter>
4. Input 103, press <Enter>
5. [103:Format] will be displayed, press 5 (Extended  SIA 3) & <Enter>
6. Input 112, press <Enter>
7. [112:Rings To Ans] will be displayed, press 0 (Any) & <Enter>
8. Input 114, press <Enter>
10. [114:CallBack] will be displayed, press 2 (Any) & <Enter>
11. [115:Tel No 1] will be displayed, press <Enter> and input telephone number<01234 567890>  & <Enter>
12. Input 117, press <Enter>
13. [117:AccountNo] will be displayed, press <Enter> and input account number and press <Enter>
14. Input 131, press <Enter>
15. [131:Mode] will be displayed, press 3 (Full) & <Enter>
16. Input 89, press <Enter>
17. [89:Confirm] will be displayed, press 0 (Off) & <Enter>